Lift-Top and Lift-Bottom Furnaces up to 1800 °C
 
 HT 276/17 LT HDB with manual table changing system and Debinding Package II HT 276/18 LTS with two ceramic retorts for sintering under protective gas

HT 64/17 LT

HT 680/17 LTS2 with table exchange system

All-round heating of the hood by means of molybdenum disilicide heating elements

High-temperature furnace HT 273/17S with table by transportable fork lift

HTC 64/14 LB or LT - HT 1440/17 LB

For charging complex settings we recommend lift-top or lift-bottom furnaces. Also small workparts can be conveniently loaded on different layers. Up to an application temperature of 1500 °C the furnaces are heated by SiC rods (HTC models). For sintering temperatures above 1500 °C these furnaces with molybdenum disilicide heating elements (HT models). Possible potential chemical interaction between the charge and the heating method can also affect the selection of heating system.

The basic furnace comes with one table. Depending on the technical requirements are equipped, a lift-top or lift-bottom version will be the choice. The system can be expanded with one or more changeable tables, either manually or electrically driven. Other additional equipment, like controlled cooling systems to short process cycles or the addition of a debinding package for debinding and sintering in one process provide for tailored solution for individual needs.

  • Tmax 1400 °C or 1500 °C (HTC models with SiC rod heating)
  • Tmax 1600 °C, 1750 °C or 1800 °C (HT models with molybdenum disilicide heating elements)
  • Double-walled housing with fan cooling provides for low shell temperatures
  • Designed as lift-top furnace with driven hood (LT) or lift-bottom furnace
  • Gently running, low-vibration spindle drive or electrohydraulic drive for larger models
  • Safe and tight closing of the furnace due to labyrinth seal and sand cup
  • Heating from all four sides provides for good temperature uniformity
  • High-quality fiber insulation backed by special insulation
  • Side insulation constructed with tongue and groove blocks provides for low heat dissipation to the outside
  • Long-life roof insulation with special suspension
  • Furnace table with special bottom reinforcement to accommodate high charge weights
  • Motor-driven exhaust air flap in the furnace roof, switchable at the program
  • PLC controls with state-of-the-art touch panel as user interface
  • Over-temperature limit controller with manual reset for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load

Additional equipment

  • Customized dimensions
  • Controlled cooling system with frequency-controlled cooling fan
  • Commissioning of the furnace with test firing and temperature uniformity measurement (also with load) for the purpose of process optimization
  • Temperature measurement with thermocouples, types B and type S with automatic pull-out device for precise control results in the low temperature range
  • Protective gas connection as well as sealing of the furnace housing to purge with protective gases
  • Manual or automatic gas supply systems
  • Gas supply system in the furnace chamber with ceramic bell jar, protective gas inlet and outlet from below for better sealing when operating with protective gases and/or to prevent from chemical interactions between the load and the insulation or the heating elements
  • Alternative table changing systems
  • Debinding Package I with passive safety package and monitoring of the underpressure in the furnace chamber, exhaust gas fan, fresh air fan, preset underpressure in the furnace chamber, controlled by Nabertherm controller P 300
  • Debinding Package II with passive safety concept
  • Emergency purging with nitrogen
  • Exhaust air and exhaust gas piping
  • Automatic changing system for thermocouple type S/B for precise measurement and control quality at lowes temperatures, e.g. in combination with a debinding package
  • Thermal or catalytic exhaust cleaning systems
  • Process documentation, display and control via HiproSystems control system
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmSupplyElectricalWeight
 °Cwdhin lWDHpower/kWconnection*in kg
HT 64/16 LB, LT1600400400400649501100235036three-phase480
HT 166/16 LB, LT160055055055016611001250250042three-phase1100
HT 276/16 LB, LT1600100050055027620001400250050three-phase1200
HT 400/16 LB, LT1600120060055040022001500250072three-phase1300
HT 1000/16 LB, LT16001000100010001000160021002800146three-phase1500
HT 1010/16 LB, LT160021506008001032320013003400156three-phase2000
HT 1440/16 LB, LT1600        three-phase 
            
HT 64/17 LB, LT1750400400400649501100235036three-phase480
HT 166/17 LB, LT175055055055016611001250250042three-phase1100
HT 276/17 LB, LT1750100050055027620001400250050three-phase1200
HT 400/17 LB, LT1750120060055040022001500250072three-phase1300
HT 1000/17 LB, LT17501000100010001000160021002800146three-phase1500
HT 1010/17 LB, LT175021506008001032320013003400156three-phase2000
HT 1440/17 LB, LT1750        three-phase 
            
HT 64/18 LB, LT18004004004006495011002350on requestthree-phase480
HT 166/18 LB, LT1800550550550166110012502500on requestthree-phase1100
HT 276/18 LB, LT18001000500550276200014002500on requestthree-phase1200
HT 400/18 LB, LT18001200600550400220015002500on requestthree-phase1300
HT 1000/18 LB, LT18001000100010001000160021002800on requestthree-phase1500
HT 1010/18 LB, LT180021506008001032320013003400on requestthree-phase2000
HT 1440/18 LB, LT1800180080010001440230029003700280three-phase2500
*Please see page 70 for more information about mains voltage
¹All dimensions without transformer housing, without hydraulic unit, and without switchgear cabinet

Információ megkérése

Nyomtatási változat

 
 
High-Temperature Chamber Furnaces with Fiber Insulation up to 1800 °C
HT 16/16 HT 160/17 with catalytic afterburning system

HT 128/17 S with lift door for opening in hot state

Protection of heating elements against mechanical damage

Fresh air injection through perforated injection tubes with Debinding Package II

Display of pressure and volume flow with Debinding Package II

Retort with gas injection through the furnace bottom protects the furnace chamber against contamination and/or prevents chemical interaction between the charge and heating elements

Gas supply system for protective gases

HT 04/16 - HT 450/18

The high-temperature chamber furnaces HT 04/16 - HT 450/18 have proven reliable over many years in the lab and in the production of technical ceramics. Whether for bioceramics, for sintering CIM components or for other processes up to a maximum temperature of 1800 °C, these furnaces afford the optimal solution for the sintering process.

High-temperature chamber furnaces can either be insulated with fiber material or lightweight refractory bricks. Furnaces with fiber insulation achieve significantly shorter heating up times because of the low thermal mass. An insulation made of lightweight refractory bricks (see HFL models on page 33), on the other hand, has the advantage of better chemical stability.

These furnaces can also be tailored to specific processes by means of a wide range of additional equipment. The addition of a debinding package, for example, allows the use of these models as combi furnaces for debinding and sintering in one process. Thermal or catalytic exhaust cleaning equipment round up the system.

  • Tmax 1600 °C, 1750 °C or 1800 °C
  • Double-walled housing with fan cooling for low shell temperatures
  • Heating from both sides via molybdenum disilicide heating elements
  • High-quality fiber insulation backed by special insulation
  • Side insulation constructed with tongue and groove blocks provide for low heat dissipation to the outside
  • Long-life roof insulation with special suspension
  • Chain-guided parallel swivel door for defined opening and closing of the door without destroying the insulation
  • Labyrinth sealing ensures the least possible temperature loss in the door area
  • Specially reinforced furnace floor for accommodating high charge weights for model HT 40 and above
  • Exhaust air opening in the furnace roof
  • Heating elements switched via SCR‘s
  • Over-temperature limit controller with manual reset for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load

Additional equipment

  • Customized dimensions
  • Controlled cooling system with frequency-controlled cooling fan
  • Commissioning of the furnace with test firing and temperature uniformity measurement (also with load) for the purpose of process optimization
  • Temperature measurement with thermocouples, types B and type S with automatic pull-out device for precise control results in the low temperature range
  • Protection grid in front of the heating elements to prevent mechanical damages
  • Protective gas connection as well as sealing of the furnace housing to purge with protective gases
  • Manual or automatic gas supply system
  • Gas supply system in the furnace chamber with ceramic bell jar, protective gas inlet and outlet from below for better sealing when operating with protective gases and/or to prevent from chemical interactions between the load and the insulation or the heating elements
  • Parallel swivel door opening upwards, also motor driven
  • Motorized exhaust air flap, switchable via the program
  • Debinding Package I with passive safety package and monitoring of the underpressure in the furnace chamber, exhaust gas fan, fresh air fan, preset underpressure in the furnace chamber, controlled by Nabertherm controller P 300
  • Debinding Package II with passive safety concept
  • Emergency purging with nitrogen
  • Exhaust air and exhaust gas piping
  • Thermal or catalytic exhaust cleaning systems
  • Process documentation, display and control via HiproSystems control system
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmSupplyElectricalWeight
 °Cwdhin lWDHpower/kWconnection*in kg
HT 04/161600150150150461047014005.2three-phase¹150
HT 08/161600150300150861061014008.0three-phase¹200
HT 16/16160020030026016710650150012.0three-phase¹270
HT 32/16160020060026032710930150018.0three-phase350
HT 40/16160030035035040810710161012.0three-phase380
HT 64/161600400400400641020840170018.0three-phase550
HT 128/16160040080040012810201250170026.0three-phase750
HT 160/16160050055055016011401020190021.0three-phase800
HT 276/161600500100055027611401470190036.0three-phase1100
HT 450/161600500115078045011401620206064.0three-phase1500
            
HT 04/171750150150150461047014005.2three-phase¹150
HT 08/171750150300150861061014008.0three-phase¹200
HT 16/17175020030026016710650150012.0three-phase¹270
HT 32/17175020060026032710930150018.0three-phase350
HT 40/17175030035035040810710161012.0three-phase380
HT 64/171750400400400641020840170018.0three-phase550
HT 128/17175040080040012810201250170026.0three-phase750
HT 160/17175050055055016011401020190021.0three-phase800
HT 276/171750500100055027611401470190036.0three-phase1100
HT 450/171750500115078045011401620206064.0three-phase1500
            
HT 04/181800150150150461047014005.2three-phase¹150
HT 08/181800150300150861061014009.0three-phase¹200
HT 16/18180020030026016710650150012.0three-phase¹270
HT 32/18180020060026032710930150018.0three-phase350
HT 40/18180030035035040810710161012.0three-phase380
HT 64/181800400400400641020840170018.0three-phase550
HT 128/18180040080040012810201250170026.0three-phase750
HT 160/18180050055055016011401020190021.0three-phase800
HT 276/181800500100055027611401470190036.0three-phase1100
HT 450/181800500115078045011401620206064.0three-phase1500
¹Only heating between two phases *Please see page 70 for more information about mains voltage

Információ megkérése

Nyomtatási változat

 
 
Chamber Furnaces with Refractory Insulation up to 1700 °C
 
 HFL 160/17 with gas supply system HFL 295/13 with lift door and transformer in stand, customer-specific design

Gas supply system for HFL 160/17

Protection grid in front of heating elements prevent against mechanical damages

HFL 16/16 - HFL 160/17

The HFL 16/16 HFL 160/17 product line is characterized by its lining with robust light weight refractory bricks. Compared with the fiber-insulated models of the HT product line, these furnaces are recommended when high charge weights have to be sintered. In most cases lightweight refractory brick insulation is also significantly more resistant to gas emissions occurring during heat treatment.

Standard equipment like HT models, except:

  • Tmax 1600 °C or 1700 °C
  • Sturdy lightweight refractory bricks and special backing insulation
  • Furnace floor made of lightweight refractory bricks accommodates high charge weights

Additional equipment like HT models

ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmSupplyElectricalWeight
 °Cwdhin lWDHpower/kWconnection*in kg
HFL 16/16160020030026016770830155012three-phase¹500
HFL 40/16160030035035040880880171012three-phase660
HFL 64/16160040040040064980930183018three-phase880
HFL 160/16160050055055016010901080203021three-phase1140
            
HFL 16/17170020030026016770830155012three-phase¹530
HFL 40/17170030035035040880880171012three-phase690
HFL 64/17170040040040064980930183018three-phase920
HFL 160/17170050055055016010901080203021three-phase1190
¹Only heating between two phases *Please see page 70 for more information about mains voltage

Információ megkérése

Nyomtatási változat

 
 
Gas-Fired Chamber Furnaces up to 1600 °C
 
HTB 645/17  

The gas-fired high-temperature furnaces of the HTB product line are specially developed for applications requiring fast heating up ramps. Gas-fired furnaces are preferred also if inflammable gases are produced in large amounts during the process. A large content of the gas emissions are already burned in the furnace chamber, so that downstream equipment like thermal and catalytic exhaust cleaners can accordingly be downsized. The furnaces are insulated with highly heat-resistant and long-life lightweight refractory brick insulation or fiber materials.

  • Tmax 1600 °C
  • Customized furnace dimensions
  • Powerful, sturdy high-speed burners with pulse control and special flame guidance in the furnace chamber provide for good temperature uniformity
  • Operation with natural gas, propane or liquified gas
  • Fully automatic PLC control of the temperature, including monitoring of the burner function
  • Gas fittings according to DVGW (German Technical and Scientific Association for Gas and Water) with flame monitoring and safety valve
  • Reduction-resistant fiber insulation with low heat storage provides for short heating and cooling times
  • Double-walled housing provides for low outside temperatures
  • Exhaust hood with fittings for further discharge of the exhaust gases
  • PLC control with touch panel as user interface

Additional equipment

  • Automatic lambda control to set the furnace atmosphere
  • Debinding package for debinding and sintering with corresponding safety technology
  • Exhaust air and exhaust gas piping
  • Recuperator burners
  • Thermal or catalytic exhaust cleaning systems
  • Process display and documentation via Nabertherm Control Center (NCC)

Információ megkérése