Chamber Kilns, Brick- and Fiber-insulated
 
N 100/G N 660/G  

Rack systems and trays for temperatures of up to 850 °C can be supplied

Chamber kiln with optional fibre insulation for shorter cycle times

N 100/G - N 2200

For many years these high-quality chamber furnaces have proven their excellent suitability for the glass industry. These models can ideally be used for cooling, bending/slumping and glass decoration.

  • Tmax 900 °C or 1300 °C
  • 5-sides heating for excellent temperature uniformity
  • Available for 900 °C for decorating, slumping/bending and cooling
  • Heating elements on support tubes provide for free heat radiation and long service life
  • Vapour vent in the middle of the roof (excellent ventilation)
  • Smoothly adjustable and easy-to-operate air inlet flap or sliding damper
  • Self-supporting arch provides for high stability
  • Models N 200..GS - N 500..S with special measurements for cooling
  • Double-walled, non-warping door with fibre seal (from model N 440..) or brick on brick for models N 100.. to N 300..
  • Special door lock for easy handling
  • Multi-layer insulation consisting of lightweight refractory bricks and backed by special fibre insulation
  • Models up to N 300/.. are supplied with a removable stand
  • Floor heating elements protected by SiC tiles to provide for level stacking floor
  • Description of the control system see page 42

Additional equipment

  • Electrically driven exhaust air damper activated via the extra function of the controller
  • Fan system for faster cooling with manual or automatic control
  • Fiber-insulation for shorter cycle times, especially cooling periods
  • Multi-zone control for optimal temperature uniformity in the useful chamber
  • Also available for 1400 °C
  • Furnace in HDB design featuring fresh air pre-heating, exhaust gas ventilation and an extensive safety package for debinding and sintering in one process, i. e. without transfering the material from the debinding furnace to the sintering furnace.
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmSupplyElectricalWeight
 °Cwdhin lWDHpower/kWconnections*in kg
N 100/G9004005304601007101150143073-phase270
N 150/G9004505305901507601150156093-phase305
N 200/G90050053072020081011501690113-phase345
N 200/GS90040010005002007101270840163-phase300
N 250/GS90050010005002508101270855183-phase370
N 300/G90055070078030086013401750153-phase430
N 360/GS90060010006003609101270955203-phase500
N 440/G9006007501000450100014501820203-phase700
N 500/GS90060014006005009101670955223-phase1000
N 660/G90060011001000660100018001820263-phase850
N 1000/G900800100012501000137018102000403-phase1680
N 1500/G900900120014001500147020102160573-phase2300
N 2200/G9001000140016002200157022102360753-phase2800
            
N 10013004005304601007101150143093-phase270
N 150130045053059015076011501560113-phase305
N 200130050053072020081011501690153-phase345
N 200/S130040010005002007101270840183-phase300
N 250/S130050010005002508101270855203-phase370
N 300130055070078030086013401750203-phase430
N 360/S130060010006003609101270955223-phase500
N 44013006007501000450100014501820303-phase700
N 500/S130060014006005009101670955243-phase1000
N 660130060011001000660100018001820403-phase850
N 10001300800100012501000145018502000573-phase1800
N 15001300900120014001500155020502160753-phase2500
N 2200130010001400160022001650225023601103-phase3100
*Please see page 42 for more information about mains voltage