| N 120/65SHA | N 500/65SHA |
N 15/65 SHA - N 500/65 SHA
Based on the standard furnaces N 30/65 HA et. al., these furnace models with air circulation are equipped with a specially sealed housing and protective gas inlet and outlet. The furnaces can be used for inert gas heat treatment allowing tempering, annealing under protective gas, and curing. You can use them also for heat-treating magnesium under certain conditions. While these furnaces are not appropriate for furnaces that require a high-purity atmosphere, they offer a compelling value for more forgiving processes.
- Maximum temperature of 650 °C
- Horizontal air circulation
- Optimum temperature uniformity (according to DIN 17052-1) up to ΔT 6 K
- Manual gas supply panel with pressure reducer and flow meter for use with all non-combustible protective gases such as nitrogen, argon or forming gas
- Heating from bottom, sides and top
- High gas circulation rate for optimal uniformity
- Supplied standard with one shelf and rails for two additional shelves
- Air baffle box of stainless steel inside the furnace chamber for optmum air circulation
- Switchgear with solid-state relays
Additional Equipment
- Automatic gas supply panel, including pressure reducer, flow meter, solenoid valves, timer
- Additional shelves
- Charging aids, roller conveyor
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Supply | Electrical | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in l | W | D | H | power/kW | connections* | in kg | |
| N 15/65SHA | 650 | 295 | 340 | 170 | 15 | 470 | 845 | 460 | 2,7 | 1-phase | 55 |
| N 30/65SHA | 650 | 290 | 420 | 260 | 30 | 607 + 255 | 1175 | 1315 | 6,0 | 3-phase¹ | 195 |
| N 60/65SHA | 650 | 350 | 500 | 350 | 60 | 667 + 255 | 1250 | 1400 | 9,6 | 3-phase | 240 |
| N 120/65SHA | 650 | 450 | 600 | 450 | 120 | 767 + 255 | 1350 | 1500 | 13,6 | 3-phase | 310 |
| N 250/65SHA | 650 | 600 | 750 | 600 | 250 | 1002 + 255 | 1636 | 1860 | 21,0 | 3-phase | 610 |
| N 500/65SHA | 650 | 750 | 1000 | 750 | 500 | 1152 + 255 | 1886 | 2010 | 31,0 | 3-phase | 1030 |
| ¹Heating only beetween two phases *Please see page 38 for more information about supply voltage | |||||||||||